There are 3 software packages available for this purpose. Logicmaster 90-30 – This is the original software for the Series 90-30. ![]() It is DOS-based and can run in Windows 95, 98 and 2000 environments. It is not supported by GE Fanuc in Windows XP and Vista environments. This is a mature product, meaning no further enhancements are planned. VersaPro Standard Edition – This is a Windows-based package and can run in Windows 95, 98, 2000 and XP environments. It is not supported by GE Fanuc in the Windows Vista environment. In addition to the Series 90-30, VersaPro Standard can also program Series 90 Micros and certain VersaMax Micro and modular PLCs. This is also a mature product. Proficy Machine Edition Logic Developer PLC Standard Edition – This is a Windows-based package and can run in Windows 2000, XP and Vista environments. Bni purpose and overview pdf example. This is the current software package for Series 90-30 PLCs. GE Fanuc Automation Programmable Control Products Logicmaster™ 90 TCP/IP. PC running Logicmaster 90 software incorporates an Ethernet card and is connected directly to the same network as the PLCs. 1-2 Logicmaster™ 90 TCP/IP Windows® 95/98 Windows NT® GFK-1401B. We have the Programming Tools needed to access your GE Fanuc Series. Logicmaster 90-30 is a DOS-based program that runs on any personal computer. All users of the LogicMaster 90-30 software versions 9.01, 9.02, and 9.05, see part numbers listed above, must update the software using the service pack referred to as?Special 2? For LogicMaster 90-30 Version 9.05, which is available from the GE Support site. CIMPLICITY is a registered trademark of GE Fanuc Automation North. Describes how to install Logicmaster 90 software on your system, configure your system. It supports all of the same PLCs that VersaPro Standard can plus a number of newer Series 90-30 and VersaMax PLC that VersaPro Standard does not. Enhancements to this software are on-going. This is the only software that will support new Series 90-30 and VersaMax CPUs and modules as they come out. To learn about these programming options,. When I try to download the configuration to my Series 90 CPU, the download fails because passwords are disabled. How do I fix this? This error occurs when the user tries to download a configuration where the CPU is configured for “Passwords Enabled” and the CPU being downloaded to is set for “Passwords Disabled.” Once passwords are disabled in a Series 90 CPU, the only way to download a configuration where the CPU is configured for “Passwords Enabled” is to completely erase the memory in the target CPU. This can be done by powering down the CPU, disconnecting the battery, and powering up the CPU with the battery still disconnected. This should clear the memory. In certain cases with the Series 90-30 CPUs, you may have to clear the memory by shorting out a super-capacitor on the CPU module by removing the CPU from the baseplate and shorting across two solder pads labeled “MEM CLR” for about 10 seconds. Once the memory is erased, a configuration with passwords enabled can be downloaded to the CPU. An alternative solution would be to change the configuration being downloaded to a “Passwords Disabled” setting and then download the configuration to the CPU. Only do this when passwords are not a concern. My Series 90 CPU stopped. How do I identify the cause? Take note of the LEDs on the power supply and the CPU. Key LEDs are the POWER LED (power supply health) and the OK LED (CPU health).If these are OK, use one of the available programming packages (), connect to the Series 90’s programming port and display the PLC and I/O fault tables. These should lead you to the root cause of the stoppage. Please note that if the CPU’s OK LED is out, the software will not communicate. My PC will not communicate to the programming port on my Series 90 CPU. Ge Fanuc Logicmaster SoftwareWhat are the possible causes of this problem? There are several possibilities: Bad port on the PC – Try using the PC’s serial port to communicate to another device in order to confirm proper operation Bad cable – Try connecting to another Series 90 PLC in order to confirm the condition of the cable. Incorrect communication settings in the software – The default settings for the Series 90 CPU programming port is 19200 BAUD, 8 data bits, 1 stop bit and odd parity. In cases where you suspect that the setting has changed and you have a copy of the PLC configuration, compare the CPU’s port configuration to your software’s port settings. Bad programming port – Check the +5 volt pin (pin 5) on the programming port versus pin 7 (0 volts). If the +5 volts is not present, the fuse for that port is blown and this fuse is not field-replaceable. If none of these suggestions solves the problem, please contact our technical support specialists at 1-866-599-6507. Can I program my Series 90-30 IC693 CPU364, CPU372 and CPU374 through the serial port on the CPU module?
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |